People judge a room by what they hear. In a meeting room, they struggle to follow a speaker; in a lobby, voices pile up; in a venue, the band blurs into the walls. Each complaint points to a property an acoustician can measure, and the acoustician designs the treatment around that property.
Separate absorption from sound insulation
Clients often ask for soundproofing when they want a quieter room. The two words describe different tasks. Absorption reduces the sound that reflects inside a room, so speech becomes easier to follow and the room calmer. Sound insulation reduces the sound that travels from one room to another, and it calls for mass, airtight joints and decoupled constructions.
Acoustic foam on a wall serves the first task and does little for the second. Name the task in the brief, so the team chooses a solution for the problem people have.
Translate the complaint into a measurement
Acousticians trace most room complaints to three properties. Reverberation time describes how long sound takes to decay by 60 dB after the source stops. The Speech Transmission Index describes how much of a talker’s speech reaches a listener intact. Background noise from building services or neighboring spaces covers speech from below.
In North America, engineers rate building-services noise with NC curves; in Europe, they use A-weighted levels. ANSI/ASA S12.60 sets 35 dB(A) for typical classrooms.
Timing matters as well. Reflections that reach a listener within about 50 milliseconds support speech, and later ones blur it.
Ask the people in the room when the problem occurs: during presentations, discussions or calls with remote participants, with the room full or empty. Their answers tell the acoustician what to measure, where to stand and which layout to record.
Set the target by the room’s use
Reverberation time depends on the room’s volume and its total absorption. Sabine’s relation shows the logic: when designers double the absorption, the reverberation time halves; when they double the volume, it doubles.
Designers set the target by use. In a classroom, every student needs to hear the teacher, and in the United States ANSI/ASA S12.60 sets a maximum reverberation time of 0.6 seconds for typical classrooms. In a meeting room with remote participants, microphones pick up the reflections along with the voice, so the room needs similar control. Musicians and audiences need some reverberation, so a music space keeps more of it.
Sports halls and swimming pools sit at the far end of the scale. Their large volumes and hard, moisture-resistant surfaces make reverberation the first problem the design team solves.
In open offices, people also deal with distraction. In an earlier research collaboration, Pinta and Fraunhofer IBP examined how absorption, shielding and sound masking affect the experience of office noise. Absorption reduces reflections, screens block the direct path between desks, and masking covers the speech that still carries, so each measure solves a different part of the problem.
Read absorption data with its mounting
Laboratories measure absorption coefficients in a reverberation room, under ISO 354 in Europe and ASTM C423 in North America. Two single-number ratings condense the results: NRC averages four frequency bands from 250 to 2,000 Hz, and the weighted coefficient αw under ISO 11654 rates the curve against a reference shape, with classes from A to E.
The same panel absorbs more at low frequencies when installers hang it with an air gap behind it than when they bond it directly to a wall. Check that the tested mounting matches the planned installation. For rooms with bass problems or music use, read the full curve, because single numbers flatten the low end.
Open-cell melamine foam absorbs most mid- and high-frequency sound at modest thickness, and sculpted or profiled surfaces add area and scatter reflections. In North America, our architectural acoustics work goes back more than 40 years with the SONEX and WILLTEC product families, from sculpted wall panels to ceiling baffles and clouds.
Place absorption where the reflections form
Acousticians place absorption where reflections form. In a meeting room, ceiling absorption controls the reflections between talkers and listeners, and panels on the wall facing a screen or a presenter remove a strong late reflection. In a music venue, treatment above the audience, near reflective windows and behind the stage reaches each surface that sends sound back.
In one historic music venue, the renovation team used this kind of distributed treatment, and together with the other works it brought the reverberation time from many seconds to under one second. The case study Making room for music follows the work.
Parallel hard walls create flutter echo, a ringing repetition after a clap or a footstep. Designers break it by treating or angling one wall of the pair.
In factories and in sorting and fulfillment centers, hard floors, walls and roofs carry machine and conveyor noise across the hall. When designers hang baffles high in the space, workers at every station hear less of the reverberant part of that noise.
Absorption works on reflected sound. When noise arrives through a partition, a door or a duct, the team treats that path with sound insulation, seals or attenuators.
Design the treatment into the architecture
Designers share the ceiling between acoustic treatment, lighting, sprinklers, air diffusers and access panels. Designers plan the hanging points and gaps of suspended clouds and baffles together with those services and choose removable fittings, so maintenance teams keep their access. Clouds over a meeting table also define a zone, and baffles in an open lobby structure the space overhead.
Architects can use light in the same decision. White melamine foam reflects a high share of light, so absorptive elements can also brighten a room. In one corporate meeting room, the architect used shaped foam on the walls, as ceiling tiles and as suspended elements, and the measured reverberation fell across the speech frequencies (case study Room for clearer speech).
For curved and irregular surfaces, the team checks physical samples against the real geometry before production. In a museum with a curved metal ceiling, the contractor used sample panels in several sizes to set the shape of the final panels; the case study Acoustics around the curve shows the sequence.
Check fire classification and installation conditions
Building authorities check the fire classification of interior finishes. In North America, manufacturers commonly classify finishes under ASTM E84, with Class A for the lowest flame spread. In Europe, test laboratories classify them under EN 13501-1, with Euroclasses and added ratings for smoke and flaming droplets.
Check the classification against the thickness and finish in your specification. In schools, gyms and venues, people touch and hit the surfaces within reach, so those surfaces need coatings or facings that withstand impact and cleaning.
Installers decide whether the tested performance reaches the room. Our contractor guide for melamine foam covers storage, acclimatization, cutting, adhesive application and suspension. Installers let panels acclimatize in the room before bonding, work on clean, dry, dust-free surfaces and confirm the adhesive on a mock-up of the substrate.
Measure after installation
Acousticians close the loop with a measurement after installation. Acousticians measure reverberation time per octave or third-octave band under ISO 3382, from 125 Hz upwards, with the same method and positions as before, and compare the result with the target agreed at the start.
An occupied room measures shorter than an empty one, so note whether furniture and people were in the room. In rooms for speech, acousticians can add an STI measurement, which shows the effect at the listener’s seat.
Two products with matching data sheets can still sound different in a room, because thickness, facing and mounting shift the absorption across frequencies. Before the contractor orders a substitute, review it with the designer and the acoustic specialist.
We support architectural projects with product information, samples, technical discussions and quotations. Tell us what people hear in the room today, and we will start the treatment from there.
Discuss your room acoustics